Permit Review Detail
Review Status: Active
Review Details: RESUBMITTAL
Permit Number - T17CM00257
Review Name: RESUBMITTAL
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/26/2018 | ALEXANDRA HINES | ZONING | REVIEW | Reqs Change | FROM: Alexandra Hines, AICP - Lead planner PROJECT: T17CM00257 2607 E Helen St Detached Carport TRANSMITTAL: November 26, 2018 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a). The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 3.11.1.B.4). In a developing area, the minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b). The applicant is proposing an 8' tall attached carport. The proposed side-yard setback is 1' to the East and the proposed front-yard setback is 12' to the South. DDO approval required prior to zoning approval. |
| 11/26/2018 | ANY | BUILDING-RESIDENTIAL | REVIEW | Active | |
| 11/26/2018 | ANY | ENGINEERING | REVIEW | Active |