| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/10/2017 | ANDREW CONNOR | ZONING | REVIEW | Reqs Change | COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1). This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). Detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line (UDC 6.6.3.B) The applicant is proposing a detached carport with a 1'1" front yard set-back and 8" side-yard setback. Additionally, the applicant is proposing an attached structure with a 13' 2" front yard setback. |
| 01/10/2017 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 01/10/2017 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 01/10/2017 | ANY | BUILDING-RESIDENTIAL | REVIEW | Active |