Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW - COMMERCIAL TI
Permit Number - T17CM00167
Review Name: 3RD PARTY REVIEW - COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/25/2017 | STANTEC | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Completed | |
| 04/25/2017 | FRODRIG2 | 3RD PARTY REVIEW-COMMERCIAL | AT 3RD PARTY OFFICE | Approved | |
| 04/26/2017 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 04/26/2017 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Principle Planner PROJECT: Via Elegante -Tucson Mountains T17CM00167 Building Plan (1st Review) TRANSMITTAL DATE: April 26, 2017 1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. Until the revision to development package DP16-0168 has been approved the building plans cannot be approved. 3. The development package sheets provided in the building plan either need to be; the signed approved development package, marked as for reference only, or removed from the building plan set. 4. Until the above comments have been addressed and all other PDSD review agencies have approved the building plans zoning cannot approve. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 04/28/2017 | MARTIN BROWN | FIRE | REVIEW | Reqs Change | On sheet A4.1.4, item 2 indicates a type 2 hood. For commercial applications utilizing appliances that could create grease laden vapors, a type 1 hood with a suppression system is required. Please revise. Please add fire alarm plans and kitchen exhaust hood fire suppression plans to list of deferred submittal on sheet T1.0. |
| 05/02/2017 | FRODRIG2 | WWM | REVIEW | Reqs Change | The following is needed for Sewer Connection Fee Application Approval: Need PCRWRD/IWC/Steven Valencia’s review of 500 gallon interceptor per drawing P1.1 (Steven.valencia@pima.gov - 520-724-6200) Need to clarify existing water meter (serial number, size & location) for sewer connection fee review. *water meter #21281644 shown on plumbing calculations P3.0 is a 6” water meter for fire sprinklers with no sewer user fees attached. |
| 05/02/2017 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/03/2017 | KROBLES1 | OUT TO CUSTOMER | Completed |