Plan Number: T16SE00141
Parcel: Unknown

Address:
3618 E PIMA ST

Review Status: Completed

Review Details: REZONING - IPC

Plan Number - T16SE00141
Review Name: REZONING - IPC
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/27/2016 STEVE SHIELDS ZONING REVIEW Completed PDSD TRANSMITTAL

TO: Planning and Development Services Department
Rezoning Section

FROM: Steve Shields
Principle Planner

PROJECT: Pathways School & Evaluation Center
3618 E. Pima Street, Parcel 122-18-0660 - R-2
T16SE00141

TRANSMITTAL: October 27, 2016

Proposed two primary uses, K-12 Elementary & Secondary School and Religious use.

Proposed K-12 School use falls under UDC TABLE 4.8-2: PERMITTED USES - URBAN RESIDENTIAL ZONES - Permitted as Special Exception Use, [2] Zoning Examiner Special Exception Procedure, Section 3.4.3

Proposed Religious use falls under UDC TABLE 4.8-2: PERMITTED USES - URBAN RESIDENTIAL ZONES - Permitted

1. The following dimensional Standards apply to the K-12 School see TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES and TABLE 6.3-2.B: EXCEPTIONS TO THE R-1, R-2, R-3, MH-1, & MH-2 DIMENSIONAL STANDARDS
a. Minimum site area = 20,000 Sq. Ft.
b. Proposed site area = 69,137 Sq. Ft.
c. Maximum building height allowed = 25 feet
d. Building height proposed = Not provided
e. Maximum Lot Coverage = 15%
f. Proposed Lot Coverage = 11.8%
g. Required Vehicle Parking = 5 spaces - Education only
h. Provided Vehicle Parking = 49 spaces
i. Required Short Term Bicycle = 2 spaces
j. Provided Short Term Bicycle = 2 spaces
k. Required Long Term Bicycle = 3 spaces
l. Provided Long Term Bicycle = 3 spaces
m. Required Passenger drop-off areas = I space
n. Provided Passenger drop-off areas = Not provided

2. The following dimensional Standards apply to the Religious use see TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES and TABLE 6.3-2.B: EXCEPTIONS TO THE R-1, R-2, R-3, MH-1, & MH-2 DIMENSIONAL STANDARDS
a. Minimum site area = 20,000 Sq. Ft.
b. Proposed site area = 69,137 Sq. Ft.
c. Maximum building height allowed = 25 feet
d. Building height proposed = Not provided
e. Maximum Lot Coverage = 60%
f. Proposed Lot Coverage = Not provided
g. Required Vehicle Parking = 43 spaces - Religious use only
h. Provided Vehicle Parking = 49 spaces
i. Required Short Term Bicycle = 2 spaces
j. Provided Short Term Bicycle = 2 spaces
k. Required Long Term Bicycle = 3 spaces
l. Provided Long Term Bicycle = 3 spaces

The submitted plan, showing the proposed Child Care is acceptable to continue the review for the zoning examiner's report.

If you have any questions about this transmittal, please call Steve Shields, (520) 836-4956 or email Steve.Shields@tucsonaz.gov.
11/04/2016 MARTIN BROWN FIRE REVIEW Approved
11/10/2016 PMCLAUG1 COMMUNITY PLANNING REVIEW Completed
11/10/2016 PMCLAUG1 ENGINEERING REVIEW Completed