Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T16PI00011
Parcel: Unknown

Address:
7500 E PIMA ST

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T16PI00011
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/26/2016 LINZUNZA UTILITY CLEARANCES COT STREETS DIVISION Denied
07/26/2016 ERNIE ENCINAS DOT_ELEC REVIEW Passed NO ELECTRICAL
07/26/2016 LINZUNZA UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Denied
07/26/2016 LINZUNZA UTILITY CLEARANCES PC WASTEWATER MGMT Denied
07/26/2016 LINZUNZA UTILITY CLEARANCES QUEST COMMUNICATION Denied
07/26/2016 LINZUNZA UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied
07/26/2016 LINZUNZA UTILITY CLEARANCES COX COMMUNICATION Denied
07/26/2016 LINZUNZA UTILITY CLEARANCES SOUTHWEST GAS CORP Denied
07/26/2016 LINZUNZA UTILITY CLEARANCES EL PASO NATURAL GAS Denied
07/26/2016 LINZUNZA UTILITY CLEARANCES KINDER MORGAN ENERGY Denied
08/10/2016 GARY WITTWER DOT LANDSCAPE REVIEW Denied There ae two small median island Fremming. Will they be landscaped? Would prefer to see them concreted in.
08/11/2016 ZELIN CANCHOLA DOT TRAFFIC REVIEW Reqs Change August 11, 2016
ACTIVITY NUMBER: T16PI00011
PROJECT NAME: Elementary Place
PROJECT ADDRESS: 7500 E Pima St
PROJECT REVIEWER: Zelin Canchola TDOT

Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan therefore a revised plan is required for re-submittal. The following items must be revised or added to the plan. Include a response letter with the next submittal that states how all comments have been addressed.

Sheet 2 of 9:

1. Revise note 3 from Striping notes to reflect this project.

Sheet 5 and 6 of 9:

1. Add no parking fire lane signs to cul de sacs

Add speed hump detail.




If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov
08/24/2016 RICHARD LEIGH DOT ENGINEERING REVIEW Denied August 19, 2016

SUBJECT: Paving Plans for Elementary Place, Lots 1-51

PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review

RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments and return redlined drawings with subsequent submittal.

1. Include the plan number "I-2016-009" in the title block of each sheet.

2. Include the PIA activity number "T16PI00011" on cover sheet.

3. Sheet 3, Detail A & B: Indicate the final surface treatment of the Median Islands.

4. Sheet 5: Verify that the proposed grades at the intersection of Chalkboard Court & Fremming Ave and Bookmark Pl & Fremming Ave will prevent stormwater flows from ponding in the intersections.

5. Sheet 5 & 6: Indicate the placement of Barricade railing along the back side of proposed sidewalk scuppers.

6. Sheet 7: Indicate that the relocated speed hump is placed per PCDOT & TDOT Traffic Engineering Division Pavement Marking Standards 5-18.1.

7. Sheet 8, Section 1: The minimum roadway cross slope for a roadway with a longitudinal grade greater that 0.5% is 2%. Verify that roadway grades and slopes comply with COT Technical Standards Manual Section 10-0.4.5.

8. Please Refer to redline plans for additional comments and comment details.

If you have any questions, I can be reached at 837-6647 or emailed at Richard.Leigh@tucsonaz.gov.
08/25/2016 LINZUNZA DOT PERMITS & CODES REVIEW Reqs Change 1. Sheet 2 - Note 6 - Asphalt Concrete should conform to City of Tucson, TDOT Mix#2. This is a new mix that is different from what is called out in section 406 of the PC/COT SS.
2. Sheet 4 - Keynote 8 - This note calls for 5 foot wide sidewalks. Detail on sheet 9 shows the sidewalk along Pima as 6 foot wide.
3. Sheet 7 - Keynote 8 - This note calls for 5 foot wide sidewalk. Detail on sheet 9 shows sidewalk along Fremming as 6 foot wide.
08/26/2016 JIM FEMLING DOT STREET MAINTENANCE REVIEW Approved
08/26/2016 LINZUNZA PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
08/26/2016 LINZUNZA PIA COORDINATOR OUT TO CUSTOMER Completed