Permit Number: T16OT01386
Parcel: 129130200

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T16OT01386
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/16/2016 PAUL BAUGHMAN ENGINEERING REVIEW Approved November 16, 2016

FLOODPLAIN USE PERMIT NO.: T16OT01386
ADDRESS: 820 E Silverlake Rd Tucson, Arizona 85713
PROPERTY OWNER: Charles Seay
5562 E Beverly St Tucson, AZ 85711

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the City of Tucson Flood Hazard Area delineation of the Colonia-Progresso Wash, specifically described as:

A portion of Parcel 129-13-0200

For the purpose of installing a manufactured home.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following 8 conditions:

1) This project is located in a mapped regulatory floodplain per the Colonia-Progresso Wash delineation per the Drainage Statement prepared by JE Fuller Hydrology and Geomorphology.

2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

3) For purposes of this permit the following flood elevations shall be used for the building:
Base Flood Elevation (BFE) = 2443.1 feet NAVD 1988
Regulatory Flood Elevation (RFE) = 2444.1 feet NAVD 1988
Bottom of the structural frame of the manufactured home and lowest point of any attached appliances to be at or above the Regulatory Flood Elevation (RFE).

4) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to manufactured home electrical inspection or habitation. The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the manufactured home as well as the identity and location of all other equipment/machinery servicing the manufactured home.

5) The manufactured home must be securely anchored.

6) The applicant may install the MH in accordance with the OMH standard, entitled "Minimum Standards for Manufactured Housing Foundations in Floodplains", sealed on 10/1/09 by Lloyd Rogers, and approved by the OMH on 10/14/09.

7) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T16OT01386 FOR INFORMATION PLEASE CALL 791-5550."

8) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

9) All work shall conform to the approved building plan, T14MH00071, which is made part of this permit.

10) This permit is specific to the improvements for 820 E Silverlake Rd as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Charles Seay
ADDRESS: 5562 E Beverly St Tucson, AZ 85711
PHONE: 520-991-3403

(EXPIRATION DATE) Month: 11 Day: 16 Year: 2017

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status