Permit Number: T16OT01078
Parcel: 11308199D

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T16OT01078
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/25/2016 PAUL BAUGHMAN ENGINEERING REVIEW Reqs Change DATE: November 25, 2016
DUE DATE: November 30, 2016
SUBJECT: NEW SFR
TO: Theresa M Riess
LOCATION: 1137 E Hendricks Drive, Unit 1
REVIEWERS: Paul Baughman, PE, CFM
ACTIVITY: T16CM06716, T16CM06716 and T16OT01078
SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed:
1) Per Tucson Code 26-5.2(8) show that the finished floor elevation is one foot above the base flood elevation.
2) Per Tucson Code 26-5.2(11) show all service facilities such as electrical and heating equipment at or above the regulatory flood elevation.
3) If at least two feet of fill is being placed on any location within the site show compliance with 2-01.8.1. If less than two feet of fill is being placed on the site add a general note indicating that less than two feet of fill is being added.
4) Per AM 2-06.4.8I show the 100-year floodplain limits and the 100-year water surface elevation upstream of each structure being proposed.
If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/09/2016 LBOJORQ1 APPROVAL SHELF Completed
12/09/2016 LBOJORQ1 OUT TO CUSTOMER Completed
12/09/2016 LBOJORQ1 REJECT SHELF Completed