Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T16OT00957
Parcel: 10922005H

Review Status: Active

Review Details: FLOODPLAIN

Permit Number - T16OT00957
Review Name: FLOODPLAIN
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
08/08/2016 PAUL BAUGHMAN ENGINEERING REVIEW Approved August 8, 2016
FLOODPLAIN USE PERMIT NO.: T16OT00957
ADDRESS: 3570 N Craycroft Tucson, Arizona 85718
PROPERTY OWNER: Craycroft River Holdings LLC
4855 E Broadway Blvd #103 Tucson, AZ 85711

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the tributary to the Tanque Verde Wash delineation, specifically described as:

A portion of Parcel 109-22-4480, Rio Verde Viallage Block 5 SQ20153560451

For the purpose of crossing a wash with irrigation equipment.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 8 conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the crossing of the wash with irrigation equipment, or, if there is any further disturbance within the floodplain other than that outlined in this application.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved Details and General site plan sheets for the demolition of the pool, which are made part of this permit.
4) The proposed wash crossing must comply with best management practices and not track sediment offsite into the public right-of-way.
5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T16OT00957 FOR INFORMATION PLEASE CALL 791-5550."
6) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
7) Any additional future disturbance or construction of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
8) This permit is specific to the improvements for 3570 N Craycroft as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Daniel Pina, Ventana Landscaping
ADDRESS: 4750 N La Cholla Blvd Tucson, AZ 85705
PHONE: 520-395-7444
Owner: Craycroft River Holdings LLC
ADDRESS: 4855 E Broadway Blvd #103 Tucson, AZ 85711
PHONE: TBD

(EXPIRATION DATE) Month: 08 Day: 08 Year: 2017

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.