06/06/2016 PAUL BAUGHMAN ENGINEERING REVIEW Reqs Change DATE: June 7, 2016
DUE DATE: June 30, 2016
SUBJECT: Floodplain Use Permit
TO: Peter Salonga
LOCATION: 2205 N Woods Place
REVIEWERS: Paul Baughman, PE, CFM
ACTIVITY: T16OT00679
SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed:
1) Update Figure 2 to show driveway routed around the basin area.
2) Call out basin area with horizontal control line work to be preserved in place for the benefit of "The Woods" Subdivision.
3) Show setback from 240 cfs wash that runs along the SE property line.
4) Show existing private drainage and turnaround easements.
5) Provide a callout that requires that the drainage flow path between the subdivision and the basin is to remain unobstructed at all times.
6) Update the water surface elevations on page 4 of the drainage report to 2586.36 for the residence and 2586.75 for the garage. Show a Minimum FFE of 2587.36 for the residence and 2587.75 for the garage. Engineer may show a higher FFE is it is in his best judgement.
If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov.