Permit Number - T16OT00481
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/05/2016 PAUL BAUGHMAN ENGINEERING REVIEW Reqs Change DATE: May 5, 2016
DUE DATE: May 11, 2016
SUBJECT: New Home Construction
TO: John Feneck
LOCATION: 2215 E Monte Vista Drive
REVIEWERS: Paul Baughman, PE, CFM
ACTIVITY: T16CM01137 and T16OT00481
SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed:
1) The Flood Zone description under project data on sheet 1 shows a BFE = 2,797. This BFE is not within the range of flood elevations for this area. Please update accordingly.
2) The site plan on sheet A1.0 needs to show existing spot elevations around the perimeter of the new building footprint per AM 2-06.4.8E.
3) Per AM 2-06.4.8H and AM 2-06.4.8I sheet A1.- needs to show floodplain flows, water surface elevations upstream of the proposed structure and the velocity of the flow at the edge of the proposed structure as determined by a civil engineer. See also AM 2-06.4.9N6 for additional requirements.
4) Per AM 2-06.4.9M a grading plan is required for this project. Submit a development package with the next submittal.
5) Per AM 2-06.4.9N4 indicate all proposed ground elevations within 10 feet of the proposed building footprint or until you tie into existing grades whichever is more extensive. Also provide the finished floor elevation per Tucson Land Code Section 26.
6) Provide drainage related notes per AM 2-06.4.7B.
If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov.