Permit Number: T16OT00404
Parcel: 116094320

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T16OT00404
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/11/2016 PAUL BAUGHMAN ENGINEERING REVIEW Approved May 20, 2016
FLOODPLAIN USE PERMIT NO.: T16OT00404
ADDRESS: 91 N Resort Hills Place, Tucson Arizona 85745
PROPERTY OWNER: Adrian R and Kristina A Federico
4180 W Golder Star Place, Tucson AZ 85712

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the Anklam Wash delineation, specifically described as:

A portion of Parcel 116-09-4320, Estates at Starr Pass Lot 7

For the purpose of constructing a residential access way for a vehicular use driveway over an existing 16 foot wide by 36 foot long and 85 inch high bridge.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 9 conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction vehicular access way, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of the vehicular access way within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved site plan sheets for the construction of the vehicular access way, which are made part of this permit.
4) The vehicular access way must be constructed such that no encroachment of the existing 16 foot wide by 36 foot long and 85 inch high bridge, as measured by the applicant, is obstructed.
5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T16OT00404 FOR INFORMATION PLEASE CALL 791-5550."
6) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
7) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
8) See the associated activity TT16CM02272
9) This permit is specific to the improvements for 91 N Resort Hills Place as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Ruben Federico
ADDRESS: 5121 W Crestview Drive, Tucson, AZ 85745
PHONE: 520-403-0163
CONTRACTOR: RCF Construction LLC
ADDRESS: 5121 W. Crestview Drive, Tucson, AZ 85745
PHONE: 520-403-0163

(EXPIRATION DATE) Month: _05 Day: 20_ Year: 2016

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/29/2016 ARUIZ1 OUT TO CUSTOMER Completed