Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T16OT00383
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/14/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Reqs Change | DATE: April 14, 2016 DUE DATE: April 22, 2016 SUBJECT: Drive-thru remodel TO: Preston Johnson LOCATION: 3310 E 22nd Street REVIEWERS: Paul Baughman, PE, CFM ACTIVITY: T16OT00383 SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed: 1) Per TSM 4-01.3 Commercial Rainwater Harvesting Standards apply to this development plan. 2) Per TSM 4-01.2.1A6 planting areas that harvest rainwater should be recessed below the grade of adjacent hardscapes. Hardscape surfaces should be sloped towards adjacent recessed planting areas. Please update Exhibit 4 and site plan to show hardscapes being routed to existing landscape area/water harvesting areas. Please show proposed depth of depressed landscaping areas such that stormwater is captured in accordance with the drainage report, AM 2-06.4.9N1 and AM 2-06.4.9N2. Please note that per Google Street View there does not appear to be any existing water harvesting from hardscapes on this site. Please update the drainage report planned conditions section to show an increase in water harvesting area per City of Tucson water harvesting standards. 3) Per AM 2-06.4.8F and AM 2-06.4.9N3 please show existing and proposed curb openings where stormwater drains off of hardscaping and into depressed water harvesting areas. 4) Per AM 2-06.4.3 please list the DP16-0051 in the title block area of each sheet. If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/26/2016 | KROBLES1 | OUT TO CUSTOMER | Completed |