Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T16OT00230
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/19/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | February 19, 2016 FLOODPLAIN USE PERMIT NO.: T16OT00230 ADDRESS: 2075 N Calle Central Tucson, Arizona 85705 OWNER: Saint Kateri Tekakwitha Roman Catholic P O Box 31, Tucson Arizona 85702 The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the City of Tucson Flood Hazard Area delineation of the Kruger floodplain Wash, specifically described as: A portion of Parcel 115-15-4130; Adelanto Lots 1 2 3 4 & 5 BLK 2 For the purpose of constructing an elevated structure at the southwest corner of the site. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. This floodplain use permit is issued with the following 8 conditions: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the demolishing of the buildings, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from demolishing the commercial building within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) For purposes of this permit the following flood elevations shall be used for the Structure: Base Flood Elevation (BFE) = 2337.68 feet NAVD 1988 Regulatory Flood Elevation (RFE) = 2338.68 feet NAVD 1988 Shed is to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE). 4) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the storage shed, if applicable, as well as the identity and location of all other equipment/machinery servicing the storage shed. 5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T16OT00230 FOR INFORMATION PLEASE CALL 791-5550." 6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 7) All work shall conform to the approved site plan, DP16-0016, which is made part of this permit. 8) This permit is specific to the improvements for 2075 N Calle Central as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Paul Pedersen - ESB Design and Build Inc. ADDRESS: 11280 W Adonis Road, Marana, Arizona 85658 PHONE: 520-682-9024 CONTRACTOR: Paul Pedersen - ESB Design and Build Inc. ADDRESS: 11280 W Adonis Road, Marana, Arizona 85658 PHONE: 520-682-9024 (EXPIRATION DATE) Month: 02 Day: 19 Year: 2016 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/22/2016 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |