Permit Number: T16CM09419
Parcel: 124062580

Address:
317 N PARK AV

Review Status: Completed

Review Details: PLANS OK TO SUBMIT - RES

Permit Number - T16CM09419
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/16/2016 LOREN MAKUS ENGINEERING REVIEW Needs Review
12/16/2016 TWEIDEM1 BUILDING-RESIDENTIAL REVIEW Needs Review
12/21/2016 STEVE SHIELDS ZONING REVIEW Reqs Change P&DS TRANSMITTAL


FROM: Steve Shields,
Principle Planner

PROJECT:
T16CM09419
317 N. Park Avenue
2nd Unit

TRANSMITTAL: December 21, 2016


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). Multi-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6, .9 & .10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

1. Based on a wall height of 16'-9" the minimum perimeter yard setback to the west property line is 11'-2", proposed perimeter yard setback is 7'-2".

2. Based on a wall height of 13'-8" the minimum perimeter yard setback to the north property line is 9'-2", proposed perimeter yard setback is 7'-4".

3. Based on a wall height of 13'-8" the minimum perimeter yard setback to the south property line is 9'-2", proposed perimeter yard setback is 7'-5".
12/21/2016 SSHIELD1 NPPO REVIEW Passed
12/22/2016 KROBLES1 WWM REVIEW Needs Review