Permit Review Detail
Review Status: Active
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T16CM09251
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/12/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Passed | |
| 12/12/2016 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 12/12/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Reqs Change | Per TSM 10-01.4.1A1a the sidewalk needs to be 5' wide along the street frontage. |
| 12/12/2016 | KEN BROUILLETTE | FIRE | REVIEW | Approv-Cond | Building is required to have an automatic fire sprinkler system installed and maintained. The fire sprinkler system shall be connected to a fire alarm system to monitor flow and tampers also. The fire alarm system shall be monitored by an approved UL listed central station. |
| 12/12/2016 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL FROM: Steve Shields, Lead Planner PROJECT: T16CM09261 700 N. 7th Avenue Convert to Group Home & Single Family Dwelling TRANSMITTAL: COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1). This site is located in the HC-1 zone (UDC 4.7.20). A Group Home is a permitted use in this zone (Table 4.8-4). Per UDC Table TABLE 7.4.4-1: MINIMUM NUMBER OF MOTOR VEHICLE SPACES REQUIRED, RESIDENTIAL USE GROUP, Single-Family - 2 spaces per dwelling unit , and RESIDENTIAL USE GROUP, Group Home - 0.5 space per resident plus 2 spaces for the resident family. Based on one (1) Single Family Dwelling and a Group Home with seven (7) residence and a resident family, eight (8) vehicle parking spaces are required on site, zero (0) on site vehicle parking spaces are provided. |