Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T16CM09111
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/10/2017 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET A-0.1; CODE REVIEW: THE APPLICABLE CODE FOR THE COVERED PARKING STRUCTURES IS THE 2012 IBC. PLEASE REVISE THE DRAWING, OR ADD A NEW CODE REVIEW FOR THE NEW PARKING STRUCTURES. 2. SHEET A-0.1; CODE REVIEW: THE OCCUPANCY GROUP FOR THE COVERED PARKING STRUCTURES IS UTILITY (U). PLEASE REVISE THE DRAWING, OR ADD A NEW CODE REVIEW FOR THE NEW PARKING STRUCTURES. 3. SHEET A-0.1; CODE REVIEW: THE CONSTRUCTION TYPE FOR THE COVERED PARKING STRUCTURES IS IIB. PLEASE REVISE THE DRAWING, OR ADD A NEW CODE REVIEW FOR THE NEW PARKING STRUCTURES. 4. SHEET A-0.1; CODE REVIEW: ADD THE SQUARE FOOTAGE OF EACH NEW PARKING STRUCTURE TO THE CODE REVIEW, OR ADD A NEW CODE REVIEW FOR THE NEW PARKING STRUCTURES. 5. SHEET A-0.1; CODE REVIEW: ADD THE ALLOWABLE SQUARE FOOTAGE FOR THE NEW PARKING STRUCTURES PER THE IBC TABLE 503, OR ADD A NEW CODE REVIEW FOR THE NEW PARKING STRUCTURES. 6. SHEET A-0.1 (SITE SECTIONS A-A, B-B, AND C-C); SHEET S1.0 (SECTION A): THE NEW PARKING STRUCTURE SECTIONS ON SHEET A-0.1 INDICATE A CANOPY WIDTH OF 16'-0", WHILE THE SECTION ON SHEET S1.0 INDICATES 17'-0". PLEASE COORDINATE. 7. SHEET S1.0; FRAMING, FOUNDATION, AND LAYOUT PLANS: THESE PLANS INDICATE AN OVERALL LENGTH OF THE NEW PARKING STRUCTURES AS 140'-0". CHANGE THE PLANS TO INDICATE THE ACTUAL LENGTHS OF EACH NEW PARKING STRUCTURE (FOUR STRUCTURES TOTAL). 8. SHEET S1.0 (FRAMING PLAN); STRUCTURAL CALCULATIONS: THE CALCULATIONS INDICATE 2-10" X 2.5" X 14 GA. BEAMS, WHILE THE FRAMING PLAN INDICATES A SINGLE 10' X 2.5" X 14 GA. 'CEE' BEAM. PLEASE COORDINATE. 9. SHEET S1.0 (FOUNDATION PLAN); STRUCTURAL CALCULATIONS: THE CALCULATIONS INDICATE 2-10" X 2.5" X 14 GA. COLUMNS, WHILE THE FOUNDATION PLAN INDICATES A SINGLE 10" X 2.5" X 14 GA. 'CEE' COLUMN. PLEASE COORDINATE. 10. SHEET S1.0; FRAMING PLAN: AN ENLARGED DETAIL 5/S1.1 IS INDICATED ON THE PLAN. THERE IS NO 5/S1.1. PLEASE VERIFY. 11. SHEET S1.1; DETAIL 8: THIS DETAIL INDICATES HOW THE PURLIN CONNECTS TO THE BEAM AT THE END OF THE BEAM. PLEASE ADD A DETAIL INDICATING HOW THE PURLIN CONNECTS TO THE BEAM AT THE MIDDLE OF THE BEAM. 12. SHEET S1.1; DETAIL 1: THE FOOTING NOTE INDICATES 8'-6" L X 4'-0" W X 2'-0" D FOOTING, WHILE THE DIMENSION BELOW THE FOOTING ON THIS DETAIL INDICATES 8'-0". PLEASE COORDINATE (A CALCULATION INDICATES 8'-0" ON A FOOTING SKETCH, BUT 8'-6" IN THE ACTUAL CALCULATION). 13. SHEET S1.1; DETAIL 1: THE COLUMN INDICATES A SINGLE 10" X 2.5" X 14 GA. MEMBER, BUT DETAIL 2 INDICATES 2-10" X 2.5" X 14 GA. MEMBERS. PLEASE COORDINATE. 14. SHEET S1.1; DETAIL 1: THE COLUMN REFERENCES DETAIL 3/S1.1 FOR THE COLUMN DETAIL. PLEASE REVISE THAT REFERENCE TO 2/S1.1. 15. SHEET S1.1; DETAIL 10: THE COLUMN REFERENCES DETAIL 3/S1.1 FOR THE COLUMN DETAIL. PLEASE REVISE THAT REFERENCE TO 2/S1.1. 16. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/13/2017 | KROBLES1 | OUT TO CUSTOMER | Completed |