Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T16CM07982
Parcel: 106030030

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T16CM07982
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/25/2016 MARTIN BROWN FIRE REVIEW Approved
10/31/2016 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Principle Planner

PROJECT: Stone Point Housing
T16CM07883 & T16CM07982
Building Plan (1st Review)

TRANSMITTAL DATE: October 31, 2016

1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Based on the provided last approved site plan it appears that changes are proposed to the vehicle parking area, a development package is required. It appears that four (4) vehicle parking spaces have been removed, provide a vehicle parking space calculation that includes the ratio used number required and provided on the development package.

3. Based on the provided last approved site plan it appears that a site wall has been added within the vehicle parking area. Per UDC Article 7.4.6.D.2.b A motor vehicle off-street parking space must have a minimum width of ten feet when the side(s) of the parking space abuts a vertical barrier over six inches in height. Per UDC Article 7.4.6.F.2.b Access lanes and PAALs must be setback at least two feet from a wall, screen, or other obstruction over six inches. Show the required 2' setback, from the wall shown north of building A, to the PAAL and provide a PAAL width dimension.

4. Demonstrate on the plan how the accessible vehicle parking spaces meet the requirements of 2012 IBC Chapter 11, section 1106.5 and the ICC A117.1-2009 Sections 502.2, 502.4, 502.5 & 502.7

5. Provide a wheel stop location dimension, see UDC Article 7.4.6.H.3.

6. Until the above comments have been addressed and all other PDSD review agencies have approved the building plans zoning cannot approve.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
11/09/2016 PIMA COUNTY MECHANICAL-COMMERCIAL REVIEW Approved
11/09/2016 PIMA COUNTY ELECTRICAL-COMMERCIAL REVIEW Approved
11/09/2016 ROBERT SHERRY WATER REVIEW Completed
11/09/2016 PIMA COUNTY BUILDING-COMMERCIAL REVIEW Approved
11/09/2016 PIMA COUNTY PLUMBING-COMMERCIAL REVIEW Approved