Permit Number: T16CM07935
Parcel: 126210620

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T16CM07935
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2016 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T16CM07935
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

SITE PLAN:

1. Show compliance with the Pool Barrier requirement by including a pool alarm system for new doors and windows opening to the pool, or show a continuous barrier around the pool, 2012 IRC Appendix G.

ELECTRICAL PLANS:

1. Panelboards may not be located in storage rooms, clothes closets or bathrooms, E3405.4. Relocate Panel A out of the bathroom.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
12/06/2016 ARUIZ1 OUT TO CUSTOMER Completed