Permit Number: T16CM07863
Parcel: 11205054B

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T16CM07863
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/24/2016 ANDREW CONNOR ZONING REVIEW Approved
10/24/2016 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Verify that the building construction allows the use of a return air plenum. Reference: 602.2, IMC 2012.
10/24/2016 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
10/24/2016 PAUL BAUGHMAN ENGINEERING REVIEW Approved October 24, 2016
FLOODPLAIN USE PERMIT NO.: T16OT01304
ADDRESS: 3122 N Campbell Ave Tucson, Arizona 85719
PROPERTY OWNER: 3122 N Campbell Ave LLC
P O Box 26927 Tucson, Arizona

The applicant is authorized to use a portion of the FEMA Special Flood Hazard Area Zone AE floodplain per the Flood Insurance Rate Maps 04019C1689L, specifically described as:

A portion of Parcel 112-05-054B, Campbell Ave Acres PTN Lots 7 & 8 LYG E & ADJ Campbell Ave BLK 4
For the purpose of remodeling an existing non-conforming building.

In reviewing this Floodplain Use Permit application for improvements to an existing floodprone structure, it has been concluded that the cumulative value of proposed improvements to this structure, as supported by documentation provided by the applicant, is less than 50% of the current value of the existing structure.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and is bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following 11 conditions:

1) All improvements proposed under this permit will be cumulative in percentage, to include this project.
2) The proposed improvements shall not impose conditions that would increase the flood damage potential to the combined proposed and existing building, by 50 percent or greater of the existing structure's value.
3) A cost estimate was used showing that the improvements are less than 50 % (estimate was 10.4%) of the Assessed Value ($866,041), as shown on the Pima County Assessors Website. No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Tucson Code. The estimate will be recorded and if piecemeal permits for this construction are applied for the cost estimate will be added to it.
4) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
5) This Floodplain Use Permit is issued concurrently with the improvement plans/permit. Copies of these documents shall be kept in a readily accessible location on site at all times.
6) Any future permanent, freestanding walls or other structures shall have separate floodplain use permit applications submitted to this office for review and approval.
7) An application/processing fee of $50.00 (submittal fee) must accompany each future request for work to be authorized under this floodplain use permit. Engineering study review fees of $150.00 may be imposed based upon the fee schedule in the current floodplain ordinance.
8) The associated improvements are with permit activity number T16CM07863.
9) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents.
10) Renewal of this permit will require a new application, review and approval of that application by the City of Tucson Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives.
11) This permit is specific to the improvements for 3122 N Campbell Ave as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Kyle Harrison
ADDRESS: 2400 W Broadway Road, Mesa, AZ 85202
PHONE: 480-414-1979
OWNER: 3122 N Campbell Ave LLC
ADDRESS: P O Box 26927 Tucson, Arizona
PHONE: TBD

(EXPIRATION DATE) Month: 10 Day: 24 Year: 2017

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.
10/24/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. SHEET A001; CODE ANALYSIS: PLEASE PROVIDE THE CONSTRUCTION TYPE ON THE DRAWING PER THE IBC CHAPTER 6. THE 'C1' INDICATED IS FOR ZONING.
2. SHEET A001; CODE ANALYSIS: THE OCCUPANT LOAD CALCULATION FOR THIS SPACE (PER THE DRAWING) IS 24. IF AN OCCUPANT LOAD OF 12 IS DESIRED, AN APPEAL MUST BE MADE TO THE BUILDING OFFICIAL TO REDUCE THAT NUMBER.
3. SHEET A002; DETAIL 6: PER THE ICC/ANSI A117.1, FIGURE 604.5.1, THE DIMENSION FROM THE FLOOR TO THE HORIZONTAL GRAB BAR IS 33" TO 36". PLEASE REVISE.
4. SHEET A002; DETAIL 6: PER THE ICC/ANSI FIGURE 604.5.1, PLEASE INDICATE THE DISTANCE FROM THE BACK WALL TO THE START OF THE HORIZONTAL GRAB BAR (12").
5. SHEET A002; DETAIL 5: PER THE ICC/ANSI FIGURE 604.5.2, PLEASE INDICATE THE DIMENSION FROM THE FLOOR TO THE HORIZONTAL GRAB BAR.
6. SHEETS A003 AND A005: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE.
7. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
10/24/2016 ROBERT SHERRY WATER REVIEW Completed
10/24/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide the minimum plumbing facilities required by Table 2902.1 and Section 2902.2, IBC 2012, for business occupancy.
2. Provide an automatic faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucet will operate for a minimum time of 10-seconds. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-03.
10/24/2016 MARTIN BROWN FIRE REVIEW Approved
10/24/2016 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
10/31/2016 ARUIZ1 OUT TO CUSTOMER Completed