Permit Number: T16CM07500
Parcel: 14117717A

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T16CM07500
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/29/2016 STEVE SHIELDS ZONING REVIEW Approved
09/29/2016 LOREN MAKUS ENGINEERING REVIEW Approved
09/30/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Coordinate the waste riser with the plumbing floor .
2. Identify all appliances that have a water connetion and identify the appropriate backflow prevention devices.
3. The distance from the water heater to the relocated fixtures that require hot water is now greater than 50-feet. See Section 607.2, IPC 2012.
09/30/2016 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
09/30/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. SHEET CS-1; INDEX OF DRAWINGS: PLEASE ADD SHEET A-3 TO THE INDEX.
2. SHEET A-2; FLOOR PLAN: THE PLAN AND KEYNOTES TITLE INDICATE NEW WALLS, BUT THE KEYNOTES INDICATE EXISTING WALLS. PLEASE INDICATE ON THE PLAN THE NEW WALLS AND CONSTRUCTION OF THOSE WALLS.
3. SHEET A-2; FLOOR PLAN: PLEASE PROVIDE THE EGRESS (INCLUDING PATH AND NUMBER OF OCCUPANTS) ON THE PLAN, OR CREATE A NEW PLAN.
4. SHEET A-2; FLOOR PLAN: PLEASE INDICATE THE TWO EXITS ON THIS PLAN.
5. SHEET A-3; KEYNOTES: NOTE 1 INDICATES DINING WALLS, BUT THE NOTE ON THE PLAN DOES NOT POINT TO WALLS. PLEASE CLARIFY.
6. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
09/30/2016 MARTIN BROWN FIRE REVIEW Reqs Change Please clearly indicate exits and number of occupants using each exit. Indicate location of panic hardware.
Unable to determine if there is wall around patio. Please clarify.
09/30/2016 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
09/30/2016 ROBERT SHERRY WATER REVIEW Reqs Change Provide the size and the serial number of the water meter serving this suite.
10/04/2016 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved