Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T16CM07500
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/29/2016 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
09/29/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
09/30/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Coordinate the waste riser with the plumbing floor . 2. Identify all appliances that have a water connetion and identify the appropriate backflow prevention devices. 3. The distance from the water heater to the relocated fixtures that require hot water is now greater than 50-feet. See Section 607.2, IPC 2012. |
09/30/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
09/30/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET CS-1; INDEX OF DRAWINGS: PLEASE ADD SHEET A-3 TO THE INDEX. 2. SHEET A-2; FLOOR PLAN: THE PLAN AND KEYNOTES TITLE INDICATE NEW WALLS, BUT THE KEYNOTES INDICATE EXISTING WALLS. PLEASE INDICATE ON THE PLAN THE NEW WALLS AND CONSTRUCTION OF THOSE WALLS. 3. SHEET A-2; FLOOR PLAN: PLEASE PROVIDE THE EGRESS (INCLUDING PATH AND NUMBER OF OCCUPANTS) ON THE PLAN, OR CREATE A NEW PLAN. 4. SHEET A-2; FLOOR PLAN: PLEASE INDICATE THE TWO EXITS ON THIS PLAN. 5. SHEET A-3; KEYNOTES: NOTE 1 INDICATES DINING WALLS, BUT THE NOTE ON THE PLAN DOES NOT POINT TO WALLS. PLEASE CLARIFY. 6. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
09/30/2016 | MARTIN BROWN | FIRE | REVIEW | Reqs Change | Please clearly indicate exits and number of occupants using each exit. Indicate location of panic hardware. Unable to determine if there is wall around patio. Please clarify. |
09/30/2016 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
09/30/2016 | ROBERT SHERRY | WATER | REVIEW | Reqs Change | Provide the size and the serial number of the water meter serving this suite. |
10/04/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved |