Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T16CM07352
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/18/2016 | CLAYTON TREVILLYAN | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 11/18/2016 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 11/18/2016 | STANTEC | BUILDING-COMMERCIAL | REVIEW | Completed | Page: Page S1.1.0 Author: Joel Svoboda Comment: Sheet S1.1.0: Response to previous comment stated that "...note is to make contractor aware that grade beam foundations may not be constructed without final wall design; however the note does not make this statement. The note could further state that "Grade beams cannot be poured until site wall package and steel building frame has been approved, and CMU wall dowels and column anchor bolts have been added to the grade beams and passed inspection". |