Permit Number: T16CM07200
Parcel: 11516024A

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T16CM07200
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/28/2016 MARTIN BROWN FIRE REVIEW Reqs Change Please provide more information about existing fire sprinkler system. Most systems are designed to an Ordinary Group II hazard classification. Once the top of storage exceed 12'-0" AFF, more water may be required from the sprinkler system. An analysis of the type of materials stored and the capabilities of the existing system must be performed by a licensed sprinkler contractor or an FPE. Additionally, our records indicate this building is overdue on required annual sprinkler inspections and a 5 year check valve inspection.
10/19/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved