Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T16CM07171
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/21/2016 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 09/23/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 09/23/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 09/23/2016 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 09/28/2016 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 10/06/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET A0.1; PROJECT DATA: PLEASE REVISE THE BUILDING DEPARTMENT TO THE CITY OF TUCSON. 2. SHEET A0.1; CODES: PLEASE REVISE THE ACCESSIBILITY CODE TO THE 2009 ICC/ANSI A117.1. 3. SHEET A0.4 (BUILDING PLAN); SHEET D1.0 (FLOOR PLAN); SHEET A1.1 (FLOOR PLAN): THESE PLANS INDICATE THE ADJACENT OFFICE SPACE 200 IS NOT INCLUDED IN THIS CONTRACT. HOWEVER, SHEET D1.2 INDICATES TO REMOVE AN EXISTING AWNING (NOTE 10) FROM THE NORTH WALL OF SPACE 200, SHEET A2.0 (ELEVATIONS 2 AND 4) INDICATE THE SOUTH AND WEST WALLS OF SPACE 200 ARE TO RECEIVE NEW STUCCO (NOTE EX1), AND SHEET A2.1 (ELEVATIONS 2 AND 4) INDICATE THE NORTH AND EAST WALLS OF SPACE 200 ARE TO RECEIVE NEW STUCCO (NOTE EX1) AND INCREASE PARAPET HEIGHT (NOTE PH). SHOULD THE REFERENCED PLANS INDICATE THE INTERIOR AREAS ARE NOT IN CONTRACT SINCE THERE ARE ALTERATIONS ON THE EXTERIOR? PLEASE VERIFY. 4. SHEET A1.1; FLOOR PLAN KEY NOTES: A T1 TRELLIS SYSTEM REFERENCES DETAIL 24/A4.2. PLEASE REVISE THE REFERENCE. 5. SHEET A1.5; FURNITURE PLAN: ON THIS SHEET, PLEASE INDICATE THE REQUIREMENTS OF THE IBC SECTION 1109.11 FOR THE MINIMUM NUMBER OF ACCESSIBLE SEATING SPACES, AND SHOW THE LOCATION OF THOSE SEATS ON THE PLAN. 6. SHEET A1.6; ELEVATION E (E1): THIS ELEVATION INDICATES ONE LAVATORY, WHILE THE PLAN (SHEET A1.1) INDICATES TWO LAVATORIES. PLEASE COORDINATE. 7. SHEETS A1.6 AND A1.7: PLEASE ADD A NOTE ON THESE SHEETS TO SEE SHEET A1.8 FOR FINISH SCHEDULES. 8. SHEETS A1.6 AND A1.7: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE GTHE FINISH SCHEDULE ITEM NUMBERS. 9. SHEET S3.1; SECTIONS 1, 2, AND 3: A NOTE IN THE UPPER WALL REFERENCES DETAIL 9/S3.4 FOR THE STUD WALL. PLEASE REVISE THE REFERENCE. 10. STRUCTURAL CALCULATIONS; PAGE 15: ARE THE SHEAR WALLS INDICATED IN THE CALCULATIONS EXISTING? PLEASE VERIFY. 11. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 10/07/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please provide complete compliance with the 2012 IECC and the TUCSON/PIMA COUNTY OUTDOOR LIGHTING CODE. REF; City of Tucson Commercial Plan Submittal Requirements, 2012 IBC 107.2.1. |
| 10/12/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Needs Review |