Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T16CM06867
Parcel: 11615088L

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T16CM06867
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/07/2016 ANDREW CONNOR ZONING REVIEW Approved
09/07/2016 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
09/07/2016 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
09/07/2016 PAUL BAUGHMAN ENGINEERING REVIEW Approved
09/07/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. SHEET g1.0; INDEX OF DRAWINGS: THERE IS NO SHEET d2.0 IN THE DRAWINGS. PLEASE REVISE.
2. SHEET g1.2; PLUMBING FIXTURE COUNT: THE WATER CLOSET COUNT INDICATES 15 REQUIRED, BUT SHOWS 3W+3M+7 PUBLIC + 1 URINAL = 14. PLEASE CLARIFY. THESE ARE EXISTING FIXTURES.
3. SHEET g1.2; PLUMBING FIXTURE COUNT: THE DRINKING FOUNTAIN COUNT INDICATES 7 REQUIRED, BUT SHOWS 6. PLEASE CLARIFY. THESE ARE EXISTING FIXTURES.
4. SHEET g1.3; FLOOR PLAN: PLEASE PROVIDE KEYNOTES AS REQUIRED.
5. SHEET a3.0: PER THE IBC SECTION 1607.14, INTERIOR WALLS NEED TO BE ABLE TO RESIST A MINIMUM HORIZONTAL LOAD OF 5 PSF. PLEASE PROVIDE DETAILS ON THIS SHEET TO INDICATE BRACING SIZE AND SPACING AT THE TOP OF THE WALL, HOW IT IS CONNECTED TO THE TOP OF THE WALL (CONNECTOR SIZE AND QUANTITY) AND HOW IT IS CONNECTED TO THE STRUCTURE ABOVE.
6. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
09/07/2016 ROBERT SHERRY WATER REVIEW Completed
09/07/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
09/07/2016 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
09/08/2016 MARTIN BROWN FIRE REVIEW Approved