Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T16CM06867
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/07/2016 | ANDREW CONNOR | ZONING | REVIEW | Approved | |
09/07/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
09/07/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
09/07/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | |
09/07/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET g1.0; INDEX OF DRAWINGS: THERE IS NO SHEET d2.0 IN THE DRAWINGS. PLEASE REVISE. 2. SHEET g1.2; PLUMBING FIXTURE COUNT: THE WATER CLOSET COUNT INDICATES 15 REQUIRED, BUT SHOWS 3W+3M+7 PUBLIC + 1 URINAL = 14. PLEASE CLARIFY. THESE ARE EXISTING FIXTURES. 3. SHEET g1.2; PLUMBING FIXTURE COUNT: THE DRINKING FOUNTAIN COUNT INDICATES 7 REQUIRED, BUT SHOWS 6. PLEASE CLARIFY. THESE ARE EXISTING FIXTURES. 4. SHEET g1.3; FLOOR PLAN: PLEASE PROVIDE KEYNOTES AS REQUIRED. 5. SHEET a3.0: PER THE IBC SECTION 1607.14, INTERIOR WALLS NEED TO BE ABLE TO RESIST A MINIMUM HORIZONTAL LOAD OF 5 PSF. PLEASE PROVIDE DETAILS ON THIS SHEET TO INDICATE BRACING SIZE AND SPACING AT THE TOP OF THE WALL, HOW IT IS CONNECTED TO THE TOP OF THE WALL (CONNECTOR SIZE AND QUANTITY) AND HOW IT IS CONNECTED TO THE STRUCTURE ABOVE. 6. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
09/07/2016 | ROBERT SHERRY | WATER | REVIEW | Completed | |
09/07/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
09/07/2016 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
09/08/2016 | MARTIN BROWN | FIRE | REVIEW | Approved |