Permit Number: T16CM06556
Parcel: 116206290

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T16CM06556
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/24/2016 ANDREW CONNOR ZONING REVIEW Approved
08/24/2016 LOREN MAKUS ENGINEERING REVIEW Approved
08/25/2016 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
08/25/2016 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
08/25/2016 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Approved
08/25/2016 MARTIN BROWN FIRE REVIEW Approved
08/25/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. All beverage dispensing appliances will require the installation of an ASSE 1022-listed backflow prevention device.
2. Verify that Pima County Waste Water will not require the use of a grease interceptor.
3. Hand sinks shall be directly-connected to the sanitary waste (with proper signage).
4.Verify the proposed location of the backflow preventer for the water service with Tucson Water (i.e. routing the water service pipe under building walls may not be acceptable to them).
5. Verify the temperature of the water discharge from the glass washer.
08/25/2016 ROBERT SHERRY WATER REVIEW Reqs Change Clarify the size of the existing water meter serving this suite. The water calculations refer to an existing 2" meter but detail 1/P1 calls out a 5/8" meter.
08/30/2016 KROBLES1 BUILDING-COMMERCIAL REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
08/30/2016 KROBLES1 OUT TO CUSTOMER Completed