Permit Number: T16CM06553
Parcel: 112062360

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T16CM06553
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/24/2016 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
08/24/2016 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Provide calculations to show that the HVAC system can accommodate the heat and moisture generated by the dish washer and that a Type II hood will not be required.
08/24/2016 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Printing errors on electrical plans.
08/24/2016 PAUL BAUGHMAN ENGINEERING REVIEW Approved
08/24/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. SHEET A1.0; CODE REVIEW (EXITING PLAN): THE REQUIREMENTS FOR THE DISTANCE BETWEEN EXITS PER 1015.2.1 ARE NOT MET FOR THE EXITS SHOWN. IF THE BACK EXIT CAN BE USED, IT WILL MEET THOSE SEPARATION REQUIREMENTS. PLEASE VERIFY AND INDICATE ON THE PLAN.
2. SHEET A1.0; CODE REVIEW (ALLOWABLE AREA): IS THIS BUILDING SPRINKLERED? THE BUILDING SUMMARY INDICATES NO, BUT THE ALLOWABLE AREA CALCULATION USES A SPRINKLER INCREASE PER SECTION 506.3 (CAN BE INCREASED BY 300%). IF NOT SPRINKLERED, THE ALLOWABLE AREA WILL BE LESS THAN THE ACTUAL AREA FOR THE ENTIRE BUILDING. PLEASE CLARIFY.
3. SHEET A1.0; CODE REVIEW (GOVERNING REGULATIONS): PLEASE REVISE THE ACCESSIBILITY CODE TO THE 2009 ICC/ANSI A117.1.
4. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
08/24/2016 ROBERT SHERRY WATER REVIEW Completed
08/24/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. The water pressure data from Tucson Water indicates that the pressure may exceed 80 PSI. Provide a pressure regulator.
2. Show the hot water return piping on the plumbing plan.
08/31/2016 KROBLES1 FIRE REVIEW Needs Review
08/31/2016 KROBLES1 ZONING REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
08/31/2016 KROBLES1 OUT TO CUSTOMER Completed