Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T16CM06498
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/22/2016 | ANDREW CONNOR | ZONING | REVIEW | Approved | |
08/22/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
08/22/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
08/22/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | |
08/22/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET A1; BUILDING CODES: THE BUILDING AREA FOR THIS TI INDICATES 1166 SF. THE OCCUPANT LOAD IS BASED ON 708 SF. PLEASE INDICATE ON THE DRAWINGS HOW THE 708 SF WAS ESTABLISHED. 2. SHEET A1; BUILDING CODES: PLEASE INDICATE THE ACTUAL USE AS A-2, BUT THE IBC SECTION 303.1.1 ALLOWS A GROUP B CLASSIFICATION (LESS THAN 50 OCCUPANTS). 3. SHEET A1; BUILDING CODES: THE EXITS INDICATE ONE, WHILE THE DRAWINGS INDICATE TWO. PLEASE CLARIFY. 4. GENERAL: THE STRUCTURAL CALCULATIONS PROVIDED INDICATE ADDITIIONS TO THE EXISTING ROOF TRUSSES AT THE NEW MECHANICAL UNIT ARE REQUIRED. PLEASE INDICATE ON THE FULL SIZE DRAWINGS THOSE REQUIRED REVISIONS. 5. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
08/22/2016 | ROBERT SHERRY | WATER | REVIEW | Completed | New 3/4" meter |
08/22/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. A ware washer is to discharge through a gravity grease interceptor but may not discharge through a hydromechanical grease interceptor. Verify how the discharge from the dishwasher can be accommodated with the Pima County Regional Wastewater Reclamation Department. Reference: Section 1003.3, IPC 2012, as amended by the City of Tucson. 2. Provide a vent downstream of the gravity grease separator to protect the seal for the grease separator. Reference: Section 1003.9, IPC 2012. 3. Verify that the discharge from the ware washer (kitchen equipment number 3) will be 140 degrees Fahrenheit or less. Reference: Section701.7, IPC 2012. |
08/22/2016 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
08/23/2016 | MARTIN BROWN | FIRE | REVIEW | Reqs Change | SAME AS BUILDING COMMENTS |