Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T16CM06378
Parcel: 116121850

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T16CM06378
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/23/2017 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T16CM06378 R1
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL COMMENTS:

1. All SFR and Duplex plans submitted after March 1, 2009 require a solar water system, or future installation preparation City of Tucson Ordinance #10549 with one of the following provisions: ½"control conduit and two ¾" copper piping for water with rooftop termination; straight 3" capped sleeve; or an accessible attic (clear path 30" wide x 30" high) over the water heater. Show appropriate notation.
2. All construction drawings submitted after June 1, 2010 for one- or two-family dwellings must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. Provide a gray drain-line discharge of all second story bathing fixtures through an exterior-wall drop for future gravity distribution. Include an aliened purple colored 2" vertical drop to a cleanout cap 2' above grade. See the PDSD web site for standard details.

FLOOR PLANS:

1. Show a maximum ½" floor elevation change at a notated accessible route entrance on the floor plan, R106.1.1. Clarify notation on sheet #2.

FOUNDATION PLANS:

1. Revise the foundation requirements for accommodating all loads, R401.2. Provide a foundation plan showing the location of footers for interior bearing walls and support posts. Sheet #5 only shows a section, but a plan is needed for location and length.

STRUCTURAL PLANS:

1. Show a beam size at with appropriate load carrying capacity, R301.1. The north upper floor wall requires load bearing to a footer. The support posts for a beam at the stairway centerline requires a minimum 24" x 24" footer.

ELEVATIONS:

1. Update the ceiling insulation notation at section B and keynote #8, sheet 5. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing (closed cell spray or rigid board tight to the roof sheathing), R806.5. This condensation control provision is necessary for code compliance, and may be a single layer of air-impermeable insulation, or layered with batt insulation for achieving the total required roof R-value.

SECTIONS - DETAILS - NOTES:

1. The plan shows the north upper level window centered on the wall line, sheet #3. Clarify the location (alignment) of this window at the north view, sheet 4, R106.1.1. Also, remove the smaller window at the north view, sheet 4 or add this window on the plan, sheet #3.

PLUMBING PLANS:

1. Revise the 2nd floor tub drain to drop down an exterior wall and connect to the building drain from this vertical location on the 1st floor plan.
2. Remove the hand written gray water notation from sheet #9. The standard detail may be added to the plans from the PDSD web site.
3. Update the isometric on sheet #9.1 showing the actual number of fixtures and separate gray water line between floors.

MECHANICAL PLANS:

1. Provide (an HVAC system with) whole-house mechanical ventilation with continuous or a minimum controlled intermittent airflow rate, R303.4 & M1507.3. Show a source of outside supply air, or a continuous exhaust fan on sheet #8.

ELECTRICAL PLANS:

1. Show Bathroom receptacles on a separate 20 AMP circuit (dedicated) with outlets at no other location, E3703.4. Change the circuit number (35) shown for the three outdoor receptacles.
2. Show or notate a disconnect means or a locking breaker for the water heater, E4101.5. Show a disconnect switch at the water heater or add notation for a locking breaker at the panel schedule circuit # 13/15.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
03/02/2017 ARUIZ1 OUT TO CUSTOMER Completed