Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T16CM06052
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/24/2016 | KROBLES1 | LANDFILL | REVIEW | Approved | APPROVED PER Thomas Ryan EMAIL SENT TO RECORDS Trish, The City of Tucson - Environmental Services Department (ES) requested additional information concerning a review of the residential property located at 3428 N. Winding River Way with respect to the landfill ordinance. The requested information was submitted by the applicant, Mariana Sherman, to ES on August 18, 2016. The submitted information was a letter report describing the methane gas monitoring conducted at the Walnut landfill on July 22, 2016. The field monitoring for methane and preparation of the July 25, 2016 report were conducted by Aplomado Environmental, Inc. from Tucson, Arizona. There are 12 nested methane gas probes at the Walnut landfill. Each nested probe has two individual probes having screens at different depths. The monitoring conducted by Aplomado Environmental, Inc. indicated a methane gas percentage of 0.0 percent (no detect) at each probe location. A portion of the 3428 N. Winding River Way property is located within 500 feet of the edge of the Walnut landfill site (the 500 foot radius around the Walnut landfill bisects the 3428 N. Winding River Way property). The Walnut landfill is approximately 4.2 acres in size and ceased accepting solid waste in 1965. ES approves the Self-Certification Statement for the 3428 N. Winding River Way property given the small size of the Walnut landfill, the time since waste was accepted at the site and the lack of methane gas detected at the site in the July 2016 monitoring event. Please call me if there are any questions concerning this review. Tom Ryan City of Tucson - Environmental Services Department >>> Thomas Ryan 8/17/2016 3:17 PM >>> Trish, The City of Tucson - Environmental Services Department completed a review of the residential property located at 3428 N. Winding River Way with respect to the landfill ordinance. The 3428 N. Winding River Way property is located within 500 feet of the Walnut landfill. The applicant (Mariana Sherman) submitted a Self-Certification Statement dated August 13, 2016, for the subject property. Prior to approving the Self-Certification Statement and to provide a more complete file for this site, please have the applicant answer the following questions: 1. Who completed the site assessment of the Walnut landfill? Did the Shermans hire an environmental consultant to perform this assessment? 2. When was the site assessment completed? 3. Where was the site assessment conducted? In the offices of the Arizona Department of Environmental Quality, City of Tucson - Environmental Services or elsewhere? The applicant can send me a short email with this information. My email address is: Thomas.Ryan@tucsonaz.gov. Thanks. Tom Ryan City of Tucson - Environmental Services Department |