Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T16CM05375
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/12/2016 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
07/12/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Coordinate the fan coil unit schedule with the COMcheck Mechanical compliance certificate; they appear to be for two different activities. 2. Provide cooling/heating load calculations. 3. Where is EF-2 located? |
07/12/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
07/12/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
07/12/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET A1.0; FLOOR PLAN KEYNOTES: NOTE 13 INDICATES A 'NEW ADA ACCESSIBLE TOILET'. IT IS CALLED OUT ON THE FLOOR PLAN FOR EVERY TOILET. ARE ALL NEW TOILETS ACCESSIBLE? PLEASE VERIFY AND REVISE AS REQUIRED. 2. SHEET A1.0; FLOOR PLAN: PER THE IBC TABLE 1018.1, IF THE NEW CORRIDOR TO THE RESTROOMS SERVES MORE THAN 30 PEOPLE AND IS NON-SPRINKLERED, A ONE HOUR RATING IS REQUIRED. PLEASE INDICATE THE NUMBER OF OCCUPANTS SERVED BY THIS CORRIDOR. 3. SHEET TS1; CODE REVIEW: PLEASE INDICATE THE OCCUPANT LOAD THIS RESTAURANT WILL SERVE, AND PROVIDE A PLUMBING FIXTURE ON THE DRAWINGS. 4. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
07/12/2016 | ROBERT SHERRY | WATER | REVIEW | Completed | |
07/12/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Provide the rim elevation of the next upstream sanitary manhole and the first floor elevation. Determine the need for a backwater valve per Section 715.1, IPC 2012, as amended by the City of Tucson. |
07/13/2016 | MARTIN BROWN | FIRE | REVIEW | Approved | |
07/18/2016 | RBENT1 | ZONING | REVIEW | Needs Review |