Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T16CM05167
Parcel: 110111110

Address:
4914 E GLENN ST

Review Status: Completed

Review Details: WALK THRU - RES

Permit Number - T16CM05167
Review Name: WALK THRU - RES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/06/2016 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Show gas pipe sizes in compliance with connected demand, G2413.3 & Table G2413.4(1). A 1" gas pipe may only supply 257,000 BTU with a 54' developed length. Show a furnace with an actual input rating less than 100,000 BTU or show a 1-1/4" pipe between the meter and first branch.

Ken VanKarsen
PDSD
837-4912