Permit Number: T16CM04237
Parcel: 13312006G

Review Status: Completed

Review Details: REVISION - - 1ST

Permit Number - T16CM04237
Review Name: REVISION - - 1ST
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/15/2016 CLAYTON TREVILLYAN BUILDING-COMMERCIAL REVIEW Reqs Change Doors with closers require 12" of clearance on the latch side of the opening when approaching from the push side of the door, Section 404, ANSI A117.1. This would seem to conflict with Section 604.9.3.1 which requires a maximum of 4" from the partition. Yet this problem is nonexistent when the door swing matches the figure provided or the compartment is large enough to accommodate the alternate 56" clearance.
07/15/2016 CLAYTON TREVILLYAN PLUMBING-COMMERCIAL REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
07/18/2016 RBENT2 OUT TO CUSTOMER Approved