Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Permit Number - T16CM03544
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/08/2016 | STEVE SHIELDS | ZONING | REVIEW | Completed | |
| 06/08/2016 | AHINES2 | ENGINEERING | REVIEW | Completed | APPPROVED PER OKAY TO SUBMIT. |
| 06/08/2016 | SSHIELD1 | NPPO | REVIEW | Completed | |
| 06/08/2016 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T16CM03544 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL COMMENTS: 1. Provide full size drawings with ΒΌ" = 1' scaled plans and legible notation (minimum 3/32" lettering). FOUNDATION PLANS: 1. Indicate the direction of slope for the garage slab, R309.1. 2. Show compliance with termite treatment, R318.2. SECTIONS - DETAILS: 1. Provide a detail of garage enclosure (family room) for the new window wall and ceiling alteration with insulation, R106. 2. Show a garage frame wall supported with a foundation stem for achieving the 6" clearance between framing and ground (R317.1 item 5) or show a ramp at the vehicle door opening. 3. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing (closed cell spray or rigid board tight to the roof sheathing), R806.5. This condensation control provision is necessary for code compliance, and may be a single layer of air-impermeable insulation, or layered with batt insulation for achieving the total required roof R-value. ELECTRICAL PLANS: 1. Show all garage receptacle outlets with GFCI protection, E3902.2. Include the ceiling receptacle on circuit #2. 2. Protect new and extended interior 15A & 20A proposed outlets (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.12. Notate circuit #6. 3. Provide notation requiring tamper resistant receptacles for 125 volt, 15A and 20A receptacles (except ceiling), R4002.14. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style, or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing is U=0.40, skylights U=0.65, ceiling R=38 (R-30 with conditions) and walls R=13. Update the maximum "U" factors of the window on sheet A1 as well as the solar heat gain coefficient SHGC minimum value of 0.25, N1102.1. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 06/09/2016 | MARTIN BROWN | FIRE | REVIEW | Approved |