Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T16CM03477
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/07/2016 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T16CM03477 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL COMMENTS: 1. An addressed living unit requires collection of development impact fee when the building permit is processed, City of Tucson Ordinance #11203. FLOOR PLANS: 1. Show the location of a minimum 22" x 30" attic access. Attic access is required for areas exceeding 30 SQ FT with a minimum of 30" of headroom and located in a hallway or readily accessible space, R807.1. PLUMBING PLANS: 1. Provide a plumbing plan for the new building, R106.1. 2. Provide pipe sizes (diameter & length), average pressure and a complete fixture unit schedule, P2903.6. Show the meter size and (existing) pipe diameter between the meter and connection point to the new building in compliance with P2903.7. 3. A second metered gas service on the property requires a separate building address. ELECTRICAL PLANS: 1. Provide a feeder conductor from the property service panel to the new building, E3602.1 & E3603.1. A second metered service panel on the property requires a separate building address. 2. Show all receptacle outlets located within 6' of a sink with ground fault circuit interrupting protection, E3902. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/09/2016 | RBENT1 | OUT TO CUSTOMER | Completed |