Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - TI ALL
Permit Number - T16CM03297
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/07/2016 | MARTIN BROWN | FIRE | REVIEW | Approved | |
06/08/2016 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera for Steve Shields PDSD Zoning Review PROJECT: Produce Warehouse Building Review T16CM03297 Related to DP16-0075 TRANSMITTAL DATE: June 8, 2016 DUE DATE: June 29, 2016 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Zoning has reviewed the building plans as it relates to the zoning review purview. While the building plans are consistent with the zoning DP Zoning cannot approve the building plans until the DP is approved. The T.I. cannot be approved until the Shell or Building plans are approved. |
06/08/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Reqs Change | Can not be approved until DP 16-0075 is approved. |
06/16/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration, states that the outer circle of the registrant's seal shall be 1-1/2" in diameter, +/- 1/16". See Appendix A of the Rules of the Arizona State Board of Technical Registration for further information regarding seals. 2. Direct reuse of reclaimed water (i.e. grey water) from a non-residential source requires a permit from the State of Arizona Department of Environmental Quality. 3. Provide the minimum plumbing facilities required by Table 2902.1, IBC 2012, for storage occupancy (e.g. service sink and two drinking fountains). 4. Provide an automatic faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucet will operate for a minimum time of 10-seconds. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-03. 5. The specified temperature mixing valve is listed as conforming to ASSE 1070 as well as ASSE 1016. Revise the specifications to note the correct standard, ASSE 1070, so that an incorrect mixing valve is not substituted. Reference: Sections 416.5 and 607.1.2, IPC 2012. 6. Revise the water demand estimate by including the continuous demand from the evaporative coolers. Reference: Section A 2.2, UPC 2012. 7. The proposed instantaneous water heater has a minimum activation rate of 0.5 GPM but the total flow rate (cold water plus hot water) for the lavatory faucet is also 0.5 GPM. Verify that the proposed water heaters will be able to provide tepid water for the lavatories. Reference: Section 607.1, IPC 2012. 8. Provide roof drainage and hydraulic scupper size calculations based on the 100-year hourly rainfall rate for Tucson, 3" per hour. Reference: Sections 1106.1, 1106.4, and 1108.3, IPC 2012. |
06/16/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration, states that the outer circle of the registrant's seal shall be 1-1/2" in diameter, +/- 1/16". See Appendix A of the Rules of the Arizona State Board of Technical Registration for further information regarding seals. 2. Clarify the number of evaporative coolers to be used; the architectural roof plan appears to show eight units. Reference: Section 107.2.1, IBC 2012. |
06/16/2016 | ROBERT SHERRY | WATER | REVIEW | Completed | |
06/29/2016 | PIMA COUNTY | BUILDING-COMMERCIAL | REVIEW | Completed | |
06/29/2016 | PIMA COUNTY | ELECTRICAL-COMMERCIAL | REVIEW | Completed |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
06/29/2016 | RBENT1 | OUT TO CUSTOMER | Completed |