Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T16CM03082
Parcel: 12411021E

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T16CM03082
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/28/2016 STEVE SHIELDS ZONING REVIEW Approved
04/28/2016 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Verify that the installer setup menu for the specified programmable thermostat includes off-hour and set-back control, automatic shutdown and automatic start-up control (i.e. the thermostat is capable of automatically adjusting the start time of the HVAC equipment in order to bring the interior conditions to the desired temperature at the start of occupancy) and, if the thermostat does not require manual changeover from the heating and cooling modes, it restricts set point overlap. Reference: Section C403.2.4, IECC 2012.
2. The occupant load used to calculate the required ventilation is not necessarily the same as the occupant load used for calculating exiting requirements. The occupant load used for calculating the minimum required ventilation is to be based on Table 403.3, IMC 2012 or an approved engineering analysis of the specific occupancy type. Reference: Section 403.3, IMC 2012.
3. Show the size, routing, and termination of the condensate drains. Reference: Section 307.2.1, IMC 2012 as amended by the City of Tucson.
4. Coordinate the scheduled outside air flows with the Air Balance Schedule.
04/28/2016 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
04/28/2016 PAUL BAUGHMAN ENGINEERING REVIEW Approved
04/28/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. SHEET G-010; CODE SUMMARY (PLUMBING FIXTURES): WITH 18 OCCUPANTS, 1 MALE AND 1 FEMALE (2 TOTAL) WATER CLOSETS ARE REQUIRED. THESE MUST BOTH BE AVAILABLE TO THE PUBLIC. THE SEPARATE FACILITIES MAY BE IDENTIFIED PER THE IBC SECTION 2902.2.1. PLEASE CLARIFY ON THE PLAN AND REVISE THE FIXTURE TABLE.
2. SHEET A-111; SHEET I-211 (ELEVATION 21): PER THE ICC/ANSI SECTION 902, THE COUNTER TOP/SINK AREA MUST BE A MAXIMUM OF 34" ABOVE FINISH FLOOR. PLEASE REVISE.
3. SHEET I-221; ELEVATION 7: PLEASE ADD A VERTICAL GRAB BAR PER THE ICC/ANSI FIGURE 604.5.1.
4. SHEET I-221: THE DRINKING FOUNTAIN MUST BE DETAILED ON THIS SHEET PER THE ICC/ANSI FIGURE 602.5. PLEASE ADD.
5. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
04/28/2016 ROBERT SHERRY WATER REVIEW Completed
04/28/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide the specifications for the temperature mixing valve shown in detail 5/P-610. Verify that the water temperature in the public lavatories will be limited to 110 degrees Fahrenheit. Reference: Section C404.3, IECC 2012.
Provide an automatic faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucet will operate for a minimum time of 10-seconds. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-03.
04/28/2016 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
04/29/2016 MARTIN BROWN FIRE REVIEW Approved