| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/02/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SEE PREVIOUS COMMENT: PLEASE PROVIDE THE NEW STEEL COLUMN BASE PLATE SIZE AND ANCHOR BOLT SIZE AND LENGTH ON DETAIL 101 ON SHEET S2. |
| 05/02/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 05/02/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | See Section 608.16.10, IPC 2012 (the 2012 IPC is the code you stated that you used to design the plumbing system); it requires a backflow preventer conforming to ASSE 1022 for all beverage dispensers. The 2006 UPC is not in use at this time but Section 603.5.12, UPC 2012 also requires the use of a backflow preventer conforming to ASSE 1022. [Initial comment: Provide an ASSE 1022-listed backflow prevention device for all beverage dispensers that are directly-connected to water.] |
| 05/02/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved |