| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/06/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 06/06/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | The revised plumbing drawings refer to the specifications to identify the manufacturer and model of the urinal. Specification Section 15400-2.5A still calls for a urinal with a back wall washdown instead of the required continuous flushing rim (i.e. Acorn Dura-Ware model 2165-CFR). [Initial comment: Verify that the specified urinal meets the hydraulic performance requirements of ASME A112.19.2/CSA. Reference: Section 419.1, IPC 2012.] |
| 06/09/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 06/10/2016 | STEVE SHIELDS | ZONING | REVIEW | Approved |