Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T16CM02272
Parcel: 116094320

Review Status: Completed

Review Details: REVISION - - 1ST

Permit Number - T16CM02272
Review Name: REVISION - - 1ST
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/22/2018 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section

PROJECT: T16CM02272
Residential- Single Family Home (1st Review of Revision) AS Built
91 N Resort Hills Place

TRANSMITTAL March 22, 2018

DUE DATE: April 6, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1. COMMENT: Zoning has reviewed the revisions to building plans but cannot approve them at this time.


2. COMMENT: The building has been altered from the original approval and prior to zoning approval a revised plot plan will be required that demonstrates the building foot print changes.


3. COMMENT: Zoning can review the revision to the building plans as well as the plot plan revision over the counter. If the zoning comments are addressed and the building footprint on the plot plan matches the as built drawing zoning will approve the plans.




4. COMMENT: Attached or detached accessory sleeping quarters may include a Single Bowl Bar Sink, under the counter refrigerator, and no cooking appliances such as a stove, range etc. The floor plan on sheet 7 shows a double bowl sink and it is not clear what type of refrigerator or if a cooking appliance was added. Clearly annotate the information.

If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Plot Plan
04/06/2018 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T18CM02272 R1
PLAN REVIEW COMMENTS


Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

GENERAL COMMENTS:

1. Cloud all changes made to the approved plans for clarifying changes.
2. The cover sheet indicates basement storage. Provide detailed plans for this addition.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
04/09/2018 LPEREZ2 APPROVAL SHELF Completed
04/09/2018 LPEREZ2 OUT TO CUSTOMER Completed
04/09/2018 LPEREZ2 REJECT SHELF Completed