Permit Number: T16CM01680
Parcel: 116205850

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T16CM01680
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/17/2016 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: T16CM01680
234 S. Avenida del Palo Fiero
Residential (1st Review)

TRANSMITTAL DATE: March 17, 2016

The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

Zoning has reviewed the residential plan for compliance with PAD-10 but until approved by the Mercado District Design Review Committee Zoning cannot approve the plans.

Once approved by the Mercado District Design Review Committee Zoning will provide an over-the-counter review.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
03/22/2016 MARTIN BROWN FIRE REVIEW Reqs Change Please add note indicating residential fire sprinklers will be installed, per previously approved development plan for the neighborhood.
03/30/2016 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T16CM01680

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

ELEVATIONS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing (closed cell spray or rigid board tight to the roof sheathing), R806.5. This condensation control provision is necessary for code compliance, and may be a single layer of air-impermeable insulation, or layered with batt insulation for achieving the total required roof R-value. Update keynote #16 sheet 5.

ELECTRICAL PLANS:

1. Show receptacle outlets at each kitchen counter space wider than 12" with no point along the wall line more than 24" from a receptacle outlet, E3901.4.1. Add a receptacle next to the range (both sides).

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
04/25/2016 KROBLES1 LANDFILL REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
04/25/2016 KROBLES1 OUT TO CUSTOMER Completed