Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T16CM01634
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/03/2016 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
03/03/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | |
03/03/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
03/03/2016 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
03/30/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. GENERAL: THE APPEAL FOR THIS PROJECT ALLOWS 40 TOTAL OCCUPANTS (STAFF AND PATIENTS). PLEASE INDICATE ON THE DRAWINGS THE MAXIMUM TOTAL OCCUPANT LOAD OF 40, ADD CALCULATIONS ON THE DRAWINGS FOR PLUMBING FIXTURES REQUIRED AND PROVIDED, AND INDICATE THE APPEAL NUMBER ON THE DRAWINGS. 2. SHEET A1.0; KEYNOTES: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE. 3. SHEET A1.0; FLOOR PLAN: PLEASE INDICATE ONE NEW RESTROOM AS MEN'S, AND ONE AS WOMEN'S. HOW IS THE SHOWER TO BE USED BY BOTH SEXES? 4. SHEET A1.0; FLOOR PLAN: SIGNAGE MUST BE POSTED FOR 40 TOTAL OCCUPANTS PER THE IBC SECTION 1004.3. PLEASE INDICATE ON THE PLAN. 5. SHEET A1.0; FLOOR PLAN: SIGNAGE MUST BE PROVIDED FOR ACCESSIBLE ELEMENTS PER THE IBC SECTION 1110. PLEASE INDICATE THOSE SPECIFIC SIGNS ON THE PLAN. 6. SHEET A1.0; FLOOR PLAN: IS THE NEW SHOWER A TRANSFER TYPE OR ROLL-IN TYPE PER THE ICC/ANSI? THE LOCATION OF THE CONTROLS PER THE ICC/ANSI SECTION 608.4 DEPENDS ON THAT DETERMINATION. 7. SHEET A1.0; CODE ANALYSIS: THE OCCUPANCY TYPE IS LISTED AS B (GENERAL BUSINESS). PLEASE REVISE. 8. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
03/30/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | This activity represents a change of use from mercantile to institutional (I-4); show that adequate ventilation is being provided. |
03/30/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Relocate the shower controls per Section 608.4, ICC/ANSI Standard A117.1-2009. |
03/30/2016 | ROBERT SHERRY | WATER | REVIEW | Reqs Change | Acording to Tucson Water, this address can expect water pressure exceeding 80 PSI. Provide a pressure regulating valve listed to ASSE 1003 to limit the water pressure to less than 80 PSI. Reference: Section 604.8, IPC 2012. |
03/30/2016 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |