Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T16CM01318
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/23/2016 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 02/23/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 02/23/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 02/23/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 02/23/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET A1.0; BUILDING CODE REVIEW (OCCUPANT LOAD): THE CALCULATED 70 OCCUPANCY LOAD IS APPROPRIATE FOR THIS USE. 2. SHEET A1.0; BUILDING CODE REVIEW (EXITS): THE DRAWING INDICATES FOUR EXITS ARE PROVIDED, BUT ONLY TWO ARE SHOWN ON THE PLAN. PLEASE CLARIFY. 3. SHEET A1.0; BUILDING CODE REVIEW (PLUMBING FIXTURES): WITH AN OCCUPANCY LOAD OF 70 (35 MALE AND 35 FEMALE), TWO WATER CLOSETS ARE REQUIRED FOR EACH SEX, ONE LAVATORY FOR EACH SEX, ONE SERVICE SINK, AND ONE HIGH/LOW DRINKING FOUNTAIN. PLEASE REVISE THE FIXTURE COUNT INDICATED. ADDITIONAL RESTROOMS MAY BE NEEDED IF THE REQUIREMENTS OF THE IBC SECTION 2902.3.2 ARE NOT MET. 4. SHEET A2.0; FLOOR PLAN: THE URINALS IN THE WOMEN'S RESTROOM ARE NOT CODE COMPLIANT. CLEARANCE IS REQUIRED (30" X 48") FOR AN ACCESSIBLE URINAL, AND THE DOORS DO NOT ALLOW THAT CLEAR SPACE. PLEASE VERIFY. 5. SHEET A2.0; FLOOR PLAN: IN THE MEN'S RESTROOM, A PARTITION (WITH A DOOR) BETWEEN THE WATER CLOSET AND THE URINAL IS REQUIRED, AS WELL AS A PARTITION BETWEEN THE URINAL AND THE LAVATORY. 6. SHEET A2.0; FLOOR PLAN: IN THE MEN'S RESTROOM, PLEASE VERIFY THE WATER CLOSET AND URINAL ARE ACCESSIBLE WITH THE PARTITIONS INCLUDED. 7. SHEET S1.1: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE THE NOTES. 8. GENERAL (STRUCTURAL): PLEASE PROVIDE STRUCTURAL CALCULATIONS AS REQUIRED. 9. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 02/23/2016 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 02/23/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Clarify the size of the RPBP; it is 1-1/4 on sheet P1.0 but 3" on P2.0. 2. Provide partitions in the men's restroom per Section 405.3.5, IPC 2015 unless it is to be a single occupancy restroom. |
| 02/23/2016 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 02/24/2016 | MARTIN BROWN | FIRE | REVIEW | Approved |