Permit Number: T16CM01219
Parcel: 138060500

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T16CM01219
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/19/2016 STEVE SHIELDS ZONING REVIEW Reqs Change P&DS TRANSMITTAL


FROM: Steve Shields,
Lead Planner

PROJECT:
T16CM01219
958 W. Calle Antonia
Permit carport & porch and existing ramada

TRANSMITTAL: February 19, 2016

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). Based on wall height of 7'-6" the required perimeter yard setback to the east property line is 6'-0", proposed is 3'-0"

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a). Based on a wall height of 11'-3" the required front street perimeter yard is 20'-0", proposed is 2'-0"

The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 3.11.1.B.4). In a developing area, the minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b). Proposed setback to the sidewalk is 4'-0" to the sidewalk and 2'-0" to the property line.
02/19/2016 SSHIELD1 NPPO REVIEW Passed
04/07/2016 KROBLES1 ENGINEERING REVIEW Needs Review
04/07/2016 KROBLES1 BUILDING-RESIDENTIAL REVIEW Needs Review