Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T16CM01130
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/18/2016 | EGALLET1 | BUILDING-COMMERCIAL | REVIEW | Needs Review | |
| 02/18/2016 | EGALLET1 | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review | |
| 03/01/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration, states that a notation shall be placed beneath the seal, either written, typed, or electronically generated, that provides the day, month, and year of the expiration of current registration. (Effective March 8, 2008). 2. Revise the architectural background to show the walls. Reference: Section 107.2.1, IBC 2012. 3. Submit the listing information for the proposed Rapid Cook Oven. Provide justification for not installing either a Type I or Type II hood over the appliance. Reference: Sections 507.1 and 507.2, IMC 2012. 4. Provide general room exhaust for any cooking appliance that does not require the installation of a Type II hood (e.g. toaster). The minimum exhaust rate shall be 0.70 CFM per square foot, using a minimum area of 100 square feet for each individual appliance. Reference: Section 507.2.2, IMC 2012. |
| 03/01/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration, states that a notation shall be placed beneath the seal, either written, typed, or electronically generated, that provides the day, month, and year of the expiration of current registration. (Effective March 8, 2008). 2. Revise the architectural background to show the walls. Reference: Section 107.2.1, IBC 2012. 3. Water supply connections to beverage dispensers (e.g. juice machines, coffee brewers, etc.) shall be protected with backflow preventers conforming to ASSE 1022. Reference: Section 608.16.1, IPC 2012. |