Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T16CM00971
Parcel: 13329015K

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T16CM00971
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/19/2016 MARTIN BROWN FIRE REVIEW Reqs Change Please provide additional documentation and/or manufacturer's cutsheets with flame and smoke spread ratings for the "woven palm leaf thatch" mentioned on details 5-A130 and 6-A130.
Verify existence of fire sprinklers.
02/22/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide automatic faucets for the lavatories, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucets will operate for a minimum time of 10-seconds. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-03.
2. Revise details 3/P3.0 and 4/P3.0 to reflect the installation requirements of the proposed water heater and the actual installation of the water heater (see detail 11/A500). Coordinate with the electrical design. Reference: Section 107.2.1, IBC 2012 and Section 303.2, IPC 2012.
3. Show how access and working space will be provided for the water heater. Reference: Section 501.4, IPC 2012.
4. Provide a watertight pan of galvanized steel (minimum 24-gage) or other approved material under the water heater with a drain to an approved location. Reference: Section 504.7, IPC 2012.
5. Provide pressure-absorbing devices for the water connections to appliances equipped with quick-acting or solenoid valves (e.g. clothes washer). Reference: Section 604.9, IPC 2012.
6. Appliances (e.g. espresso machines, ice makers, etc) to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps conforming to Section 608.13.1, IPC require backflow prevention. Specify the type of backflow prevention device required for each water connection. Reference: Sections 608.1, 608.3, and 608.16.10, IPC 2012.
7. Provide cleanouts sized for the nominal size of pipes that they serve up to 4-inches. Reference: Section 708.7, IPC 2012.
8. Revise the venting for the two floor sinks located along the east side of the sales area. With the exception of vents serving interceptors located outdoors, all vents shall rise vertically to at least 6" above the flood rims of the fixtures they protect prior to running horizontally. Reference: Section 905.4, IPC 2012.
9. The use of hydromechanical grease interceptors is limited to installations having four or fewer fixtures connected to a grease interceptor. Reference: Section 1003.3, IPC 2012 as amended by the City of Tucson.
10. Hand sinks in the food preparation area are allowed to connect to the sanitary waste system instead of the grease waste system only if each sink has a sign posted above it stating, "HANDWASH SINK ONLY! NO FOOD PREPARATION OR DISHWASHING ALLOWED." Reference: Section 1003.3, IPC 2012, as amended by the City of Tucson.
11. Connect the dipper well (equipment #46) to grease waste. Reference: Section 1003.3.2, IPC 2012.
02/22/2016 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Revise and coordinate the General New Notes (M1.0) and the specifications on sheet M2.0 as required to apply to this activity (e.g. differing duct insulation instructions, non-existent heat pumps, and possibly non-existent economizers, etc.). Reference: Section 107.2.1, IBC 2012.
2. Revise the sequence of operation for the restroom exhaust fan so that all of the air supplied to the restrooms will be exhausted (i.e. the exhaust fan shall operate whenever supply air is being delivered to the restrooms, even if the lights are off). Reference: Section 403.2.1 (4), IMC 2012.
3. Show the size, route, and termination of the dryer exhaust duct. Reference: Sections 504.1, 504.2, 504.4 and, 504.6, IMC 2012.
4. The architectural and mechanical floor plans appear to show a bi-fold door at the stacked washer/dryer location. Show how the dryer installation complies with Section 504.5, IMC 2012 for make-up air.
02/22/2016 ROBERT SHERRY WATER REVIEW Reqs Change Show the location of the reduced pressure backflow assembly on the drawings; indicate the size of the assembly. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, http://www.tucsonaz.gov/files/water/docs/backflow-ordinance.pdf.
03/03/2016 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Denied While the electrical review for the current submittal is approved, due to the potential modifications necessary to address comments associated with the reviews of other disciplines the electrical workflow is denoted as denied in order to verify that those modifications will not adversely impact the electrical review.
03/10/2016 STEVE SHIELDS ZONING REVIEW Needs Review PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Bahama Bucks
T16CM00971
Building Plan (1st Review)

TRANSMITTAL DATE: March 10, 2016

1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. There appears to have been an addition of an outdoor seating area, Either provide documentation that the outdoor seating area was permitted or provide a development package meeting the requirements of Administrative Manual Section 2-06.

3. Zoning cannot approve the building plan until the outdoor seating has been approved.

4. Until the above comments have been addressed and all other PDSD review agencies have approved the building plans zoning cannot approve.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
03/11/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. SHEET G1; PROJECT DATA: THIS OCCUPANCY TYPE CAN EITHER BE A RESTAURANT (A-2) OR A FACTORY (F-1). IF A RESTAURANT, INDICATE A-2 ON THE DRAWING WITH THE REFERENCE TO THE IBC SECTION 303.1.1 FOR B CLASSIFICATION. THE F-1 MIGHT BE THE BEST DESCRIPTION SINCE 'FOOD PROCESSING AND COMMERCIAL KITCHENS NOT ASSOCIATED WITH RESTAURANTS' IS MORE ACCURATE. THIS WOULD NOT CHANGE YOUR CALCULATED OCCUPANCY LOAD.
2. SHEET G2; SITE PLAN: A NOTE INDICATES THE OUTDOOR PATIO WILL BE ON A SEPARATE PERMIT. DID THE OCCUPANCY LOAD OF 46 INCLUDE THE PATIO OCCUPANTS? PLEASE VERIFY.
3. SHEET A100; EGRESS AND FLOOR PLANS: WHY IS THE TURNING SPACE CIRCLE INDICATED IN THE SALES AREA? PLEASE VERIFY.
4. SHEET A110; DETAIL 2: PLEASE INDICATE THE DIAGONAL BRACING SIZE AND SPACING ON THE DETAIL. INCLUDE THE CONNECTOR SIZES AND QUANTITIES FOR THE CONNECTION OF THE BRACE TO THE TOP OF THE WALL AND TO THE STRUCTURE ABOVE.
5. SHEET A130; REFLECTED CEILING PLAN: PLEASE INDICATE THE EXIT SIGN AT THE EAST EXIT DOOR.
6. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
03/11/2016 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
03/16/2016 LOREN MAKUS ENGINEERING REVIEW Approved