Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T16CM00963
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/02/2016 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 03/02/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 08/29/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 08/29/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Show that the new walls and exterior door meet the requirements of the Sections 303, 401, and 402, 2012 IECC. 2. Provide the sequence of operation for the restroom exhaust fan and verify that the exhaust flowrate is at least equal to the A/C supply to the restroom. |
| 08/29/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET S1: PLEASE PROVIDE STRUCTURAL CALCULATIONS FOR THE NEW EXTERIOR WALLS. INCLUDE DETAILS ON THIS SHEET AS REQUIRED FOR WALL AND FOUNDATION. 2. SHEET A1.1; FLOOR PLAN: THE DOOR INTO THE ACCESSIBLE RESTROOM MUST MEET THE MANEUVERING CLEARANCES AS INDICATED IN THE 2009 ICC/ANSI FIGURE 404.2.3.2(a). 3. GENERAL: PLEASE PROVIDE A DETAIL ON THE DRAWINGS INDICATING LATERAL BRACING FOR THE NEW INTERIOR STUD PARTITION PER THE IBC SECTION 1607.14. INCLUDE BRACING SIZE AND SPACING, AND CONNECTION (SIZE AND QUANTITY) OF THE BRACE TO THE PARTITION WALL AND TO THE STRUCTURE ABOVE. 4. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 08/29/2016 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
| 08/29/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide specifications for the new plumbing fixtures. All fixtures shall be 3rd party listed. 2. The lavatory faucet shall be a metering faucet that dispenses no more than 0.25 gallons per cycle. 3. Provide tempered water for the lavatory using a mixing valve listed to ASSE 1070. 4. Show how the waste piping will be connected to the existing waste piping. |
| 08/29/2016 | ROBERT SHERRY | WATER | REVIEW | Reqs Change | 1. Provide the size of the water meter serving the office area and the total demand that it serves. 2. Show the size and location of the reduced pressure backflow preventer. |
| 08/29/2016 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |