Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T16CM00890
Parcel: 141220280

Address:
9255 S RITA RD

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T16CM00890
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/22/2016 KEN BROUILLETTE FIRE REVIEW Completed
02/22/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
02/22/2016 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the following electrical plan review comments.
#1. Provide compliance with section 402.1 ( color temperature ) of the Tucson/Pima County Outdoor Lighting Code. Reflect this on the luminaire spec's and schedules.
Ref: IBC sec.107.2.1, 2011 NEC, Tucson/Pima County
#2. Provide compliance with NEC art. 250.32 at the separate structures ( fuel canopies )
02/25/2016 LOREN MAKUS ENGINEERING REVIEW Approved
02/29/2016 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Carioca - Shell & 2 Fuel Canopies
T16CM00824, T16CM00829 & T16CM00890
Building Plan (1st Review)

TRANSMITTAL DATE: February 29, 2016

1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. It does not appear that the site plan provided in this set of drawings matches grading plan DP15-0173, the access to the billboard has changed. DP14-0167 will also need to be revised to match the grading plan.

3. Until the building plan has been approved by all PDSD agencies Zoning cannot approve.

4. Until the above comments have been addressed and all other PDSD review agencies have approved the building plans zoning cannot approve.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
03/01/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. GENERAL: THE SPECIAL INSPECTION FORM FOR THIS PROJECT NEEDS A REGISTRANT'S SEAL AND SIGNATURE, AND A LIST OF THE SPECIFIC INDIVIDUAL'S NAME FOR EACH SPECIAL INSPECTION. IS THERE ANY WELDING ON THIS PROJECT?
2. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/16/2016 EGALLET1 OUT TO CUSTOMER Completed