Permit Review Detail
Review Status: Active
Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Permit Number - T16CM00619
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/26/2016 | ANY | ENGINEERING | REVIEW | Active | |
| 01/26/2016 | ANY | BUILDING-RESIDENTIAL | REVIEW | Active | |
| 02/01/2016 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | P&DS TRANSMITTAL FROM: David Rivera, Principal Planner TRANSMITTAL: January 29,2016 ADDRESS: 1915 E 10th Street ACTIVITY NO: T16CM00619 ZONE: R-1 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). Review of this permit application is for a single family dwelling with five bedrooms. Compliance with R-1 regulations: For 1 unit, 4.9.7.B.5 - 9; A group dwelling is not allowed in the R-1 Zone. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The owner is proposing to build additions to the existing dwelling. Due to the design and heights of the proposed additions, DDOs for the building setbacks will be required for the sections of the building that will encroach into the north, west and east building setbacks. Refer to the site plan sheet for information related to the proposed building setbacks. West Perimeter yard 1. Southwest wall height of 12'- 6" above grade requires a setback of 8'- 4" / Proposed 7'- 3" setback 2. Bathroom pop-outs wall height of 12'- 8" above grade requires a setback of 8'-5" / Proposed 3'-3" setback 3. Southwest wall height of 14'- 8" above grade requires a setback of 9'- 9" / Proposed 7'- 3" setback 4. Staircase along the northwest wall encroaches into the 6 foot building setback / Proposed 2'- 0" setback 5. Two story addition with a wall height of 24'-5" above grade requires a setback of 16'- 4" / Proposed 5'- 0" setback North Perimeter yard 1. Two story addition with a wall height of 24'-5" above grade requires a setback of 16'- 4" / Proposed 5'- 0" setback East Perimeter setback 1. Two story addition with a wall height of 22'-8" above grade requires a setback of 15'- 1" / Proposed 3'- 0" setback 2. Kitchen Pop-out with a wall height of 14'- 4" above grade requires a setback of 9' - 6" / Proposed 6'-2" Setback |
| 02/01/2016 | DAVID RIVERA | NPPO | REVIEW | Passed |